- Plug-and-pump installation without having to worry about overheating.
- Pumps with a built-in AquaTronic unit will adjust incorrect phase order, ensuring correct impeller rotation.
- A wide range of pumps, up to 11 kW, makes it easy to find a solution for any pumping need.
- Clog-free pumping with pumps designed for pumping sludge and water mixed with solids.
- Non-overloading performance with two different impellers for each pump model. The small impeller allows the pump to run in low-level applications.
- Serviceability with modular design. Pumps with a built-in AquaTronic can be checked without disassembly, using its service software.
Submersible sludge pump XJS 25
Slender designs for optimal pumping
- XJS 25 D -128 3-phase 50 Hz
- XJS 25 D -128 AT* 3-phase 50 Hz
- XJS 25 D -143 3-phase 50 Hz
- XJS 25 D -143 AT* 3-phase 50 Hz
- XJS 25 D -118 3-phase 60 Hz
- XJS 25 D -118 AT* 3-phase 60 Hz
- XJS 25 D -128 3-phase 60 Hz
- XJS 25 D -128 AT* 3-phase 60 Hz
Weight: 39 kg (86 lb)
*AquaTronic: Built in electronic pump control.
AquaTronic option
The AquaTronic unit (AT) replaces the built-in contactor in the basic pump configurations and ensures that the motor always rotates correctly, no matter how the phases are connected. Key benefits of the AquaTronic unit include:
- Correction of motor rotation if phases are improperly connected
- Run mode (no panel needed)
- Integrated start equipment (direct or soft start depending on pump model)
- Motor protection against high temperature, high amperage and missing phase
- Anti-clog function
If the pump is also equipped with an optional level sensor, AquaTronic provides:
- Precise level control
- Protection against dry running
- Energy save mode (energy is saved through stopping at dry run and starting by level sensor)
AquaTronic service diagnostic program
Connecting a PC to the AquaTronic unit via USB cable provides access to the service diagnostic program, which offers:
Pump status data, pump operating history, pump failure history, pump service/maintenance history, digital manual and spare part documentation
AquaPlug (50 Hz only)
AquaPlug is an option that combines with AquaTronic to provide additional alarm and start/stop functions, as well as indications for important parameters.
Starting method and motor protection
XJS25 AT: Direct on line start (DOL 230-550 V 50 Hz / 230-575 60 Hz) with built in AquaTronic unit, which automatically adjusts phase order by dual contactors, ensuring correct motor rotation. The AquaTronic unit monitors motor temperature, by use of NTC thermistors built into stator windings, and stops the motor at high temperature. It will also stop the motor at high amperage or if a phase is missing.
XJS25: Direct on line start with built in contactor. Pumps to be used with VFD or 1,000 V must have terminal block instead of contactor.
Thermal switches (140ºC / 284ºF, ±5) built into the stator windings are connected to the contactor and stops the pump at high temperature.
Discharge connections
2 1/2”, 3” (standard), 4” hose connections |
2 1/2”, 3”, 4” G/B.S.P. threaded connections |
2 1/2", 3", 4" NPT threaded connections |
Storz coupling available as an accessory
Plug-and-pump installation
Plug in without having to worry about overheating. Built-in contactor and thermal sensors protect the motor from overheating. Pumps with a built-in AquaTronic unit will adjust electronically for incorrect phase order, ensuring correct impeller rotation.
Reliable and trouble-free operation
The XJS is perfect for pumping sludge and water mixed with solids as it is equipped with a free-flow vortex impeller and a pump volute. The pump design, the robust construction and the premium materials ensure high wear resistance, and the impeller is available in different sizes to meet your specific requirements.
Serviceability
The modular design of the pump range reduces costs by ensuring maximum pump availability with a smaller spare parts inventory. The condition of a pump with a built-in AquaTronic unit can be rapidly checked without disassembly, using its service software.
Saves energy and the environment
The high-efficiency motor and hydraulics are combined with low-friction bearings to reduce power losses. You achieve low total energy costs and minimize your carbon footprint. Environmentally safe white oil is used in the oil casing for easy inspection of seal conditions.
Electric submersible pump | XJS 25 |
Maximum submergence | 20 m |
Protection class | IP 68 |
Max. temperature of pumped medium at max. power input and continuous duty | 40ºC |
Max. media density | 1,100 kg/m3 |
pH of the pumped medium | 5-8 |
Free passage | 45 x 55 mm |
Max number of starts | 30/hour |
Motor rating P2 | 2.5 kW |
Speed | 2,920 rpm |
Power cable | 20 m type H07RN8-F |
Electric submersible pump | XJS 25 |
Maximum submergence | 20 m |
Protection class | IP 68 |
Max. temperature of pumped medium at max. power input and continuous duty | 40ºC |
Max. media density | 1,100 kg/m3 |
pH of the pumped medium | 5-8 |
Free passage | 45 x 55 mm |
Max number of starts | 30/hour |
Motor rating P2 | 2.9 kW |
Speed | 3,500 rpm |
Power cable | 20 m type H07RN8-F |
Electric submersible pump | XJS 25 |
Maximum submergence | 65 ft |
Protection class | IP 68 |
Max. temperature of pumped medium at max. power input and continuous duty | 104ºF |
Max. media density | 0.0397 lb/inch3 |
pH of the pumped medium | 5-8 |
Free passage | 2 3/16" x 1 3/4" |
Max number of starts | 30/hour |
Motor rating P2 | 4 Hp |
Speed | 3,500 rpm |
Power cable | 65 ft type AWG |